AKW 10 series
Daikin AKJW 1500px.png
Daikin Long Live Filter 1500px.png
AKW 10 series
Daikin AKJW 1500px.png
Daikin Long Live Filter 1500px.png
Daikin

Fluid cooling units Daikin

Realization of high energy saving performance

Daikin

Realization of heat control with high precision

Energy-saving inverter cooling units

Realization of a high energy saving performance

  • Approximately 20% savings (compared to our company's non-inverter units).

Realization of heat control with high precision

  • Temperature control: ±0.1°C (AKZ series: heat load: 5-100% stability) (AKZJ series: heat load: 30-100% stability)
  • Auto-tuning function.
  • Leaking refrigerant gas detection function.
  • Timer function for 99 hours.

______________________________________________________________________________________________________________________________________________________________________________________________

AKZ oil cooling system series 10 (circulation type)

High precision inverter oil chiller (circulation type, for oil)

The AKZ Series 10 is Daikin's brand new range of oil coolers that are even more compact and easier to maintain than their predecessors.

  • High precision temperature control with Daikin inverter.
  • Improved energy saving performance.
  • An extended cooling capacity range.
  • The design complies with the latest environmental regulations.
  • The unit achieves low operating noise in the low load range*.

More compact design

  • 400 V chiller without transformer, minimizing the size of the appliance.

Easier maintenance

  • The air filter has been improved to reduce the amount of cleaning required in the event of oil mist blockages, preventing sudden stoppages and downtime.

Technical data

  • Cooling capacity: 1.3 - 9.0 KW
  • Refrigerant: R-410A
  • Supply voltage: 3-phase AC; 380 - 400 - 415 V
  • Delivery rate of the oil pump: 12 - 36 l/min

______________________________________________________________________________________________________________________________________________________________________________________________

AKW water chiller series 10

High-precision inverter-controlled cooling system (circulation type for cooling with water / ethylene glycol solution)

Lightweight, compact and transformerless 400 V chiller

  • The dimensions are the same as the standard models (200 V), so no design changes are required for other voltages.

Easier to use, with an extended application range

  • Extended operating temperature range (AKW14A to 45A only) 5°C - 45°C
  • Ethylene glycol solution added to the usable fluids

Excellent high-precision temperature control

  • Highly accurate ±0.1°C oil temperature control
  • The resolution of the cooling capacity in the low-load range has been improved by optimizing the control of the compressor/inverter and the electronic expansion valve.
  • ±0.1°C oil temperature control over a load range from 0% (no load) to 100%.

Technical data

  •     Cooling capacity: 1.4 - 9.2 KW
  •     Refrigerant: R-410A
  •     Supply voltage: 3-phase AC; 380 - 400 - 415 V 50/60Hz

______________________________________________________________________________________________________________________________________________________________________________________________

AKJ Series 10 oil cooling system

High-precision inverter-controlled oil cooling system Immersion type for cutting/grinding fluid (oil)

High precision temperature control

  • High-precision ±0.1°C fluid temperature control
  • The resolution of the cooling capacity in the low-load range has been improved by optimizing the control of the compressor/inverter and the electronic expansion valve.
  • A liquid temperature control of ±0.1°C has been realized over a load range from 0% (no load) to 100%.

Reduced environmental impact

  • Complies with environmental regulations, e.g. by using printed circuit boards with lead-free solder.

Lightweight transformerless 400 V specifications now available

  • Dimensions are the same as the standard models, so no design changes are required for different voltages.
  • Mass is significantly lower than Series 9 (27% reduction)

Technical data

  • Cooling capacity: 1.8 - 9.0 KW
  • Refrigerant: R-410A
  • Supply voltage: 3-phase AC; 200 - 480 V 50/60Hz

______________________________________________________________________________________________________________________________________________________________________________________________

AKC liquid cooling system Series 9 (Discontinued model)

High-precision inverter-controlled oil cooling (circulation of the coolant)

Outstanding energy savings

  • The compressor is equipped with a highly efficient original Daikin IPM motor. High energy savings are achieved thanks to the inverter control technology, which is based on our experience in air conditioning technology and the refrigerant R410A, which has a high COP value. (Approx. 30% energy saving compared to Series 8)

Easy maintenance

  • The design of the evaporator heat exchanger has been improved to increase durability against clogging. In addition, the evaporator coil is easy to dismantle and clean.

Greater resistance to oil mist and dust

  • The protection class of the switch box has been improved to IP54, including the use of sulphur-free parts.

Existing functions:

  • Refrigerant gas leak detection function. If a refrigerant gas leak occurs (cooling disabled), alarm signals are issued. Prevents damage to the machine and machining errors.
  • Temperature warning function. A warning signal can be emitted if the target liquid or air temperature is outside the freely selectable setting range.
  • Autotuning function. This function minimizes the setting time for trial operation by automatically setting the increase if the liquid temperature control is not stable with the factory setting or if optimization is required.
  • 999-hour timer function (ON timer) The operating start time can be set in a range between 0 and 999 hours (in units of hours).

Technical data

  • Cooling capacity: 3.5 - 5.6 KW
  • Refrigerant: R-410A
  • Supply voltage: 3-phase AC; 200 - 220 V 50/60Hz

______________________________________________________________________________________________________________________________________________________________________________________________

AKZW Series 9 oil cooling unit (Discontinued model)

High-precision inverter oil cooling unit (circulation type for oil)

Little to no “waste heat” from the oil cooler.

  • Enables working in a comfortable environment
  • Reduces the air conditioning load in the factory and saves energy
  • Enables stable performance of machines that require precise temperature control in the factory

Significantly reduces the time required to clean a clogged condenser

  • Use of a double-tube condenser that is resistant to clogging
  • Reliable device for long-term use

High-precision temperature control by inverter-controlled compressor

  • The oil temperature can be controlled within ±0.1°C over the entire cooling load range (from 0 to 100% load), which improves the accuracy of the machine tool.

Specifications

  • Cooling capacity: 1.4 - 9.0 KW
  • Refrigerant: R-410A
  • Power supply: 3-phase AC; 200 - 220 V 50/60HZ

______________________________________________________________________________________________________________________________________________________________________________________________

AKJW liquid cooling unit Series 9 (Discontinued model)

High-precision inverter-controlled oil cooling unit (immersion type for cutting/grinding fluid (oil))

Little to no “waste heat” from the oil cooler.

  • Enables working in a comfortable environment
  • Reduces the air conditioning load in the factory and saves energy
  • Enables stable performance of machines that require precise temperature control in the factory

High-precision temperature control thanks to inverter-controlled compressor

  • The oil temperature can be controlled with an accuracy of ±0.1°C over the entire cooling load range (from 0 to 100% load), which improves the accuracy of the machine tool.

The specifications are compatible with those of the air-cooled units. (cooling capacity, external dimensions, etc.)

  • Easy replacement of an existing air-cooled condenser unit with this water-cooled model when cooling water is available.

Technical data

  • Cooling capacity: 1.6 - 9.0 KW
  • Refrigerant: R-410A
  • Power supply: 3-phase AC; 200 - 220 V 50/60HZ

______________________________________________________________________________________________________________________________________________________________________________________________

Accessories

Long-life filter for oil cooler

  • Change the filter only once a year!
  • Cooling fins do not need to be cleaned!

______________________________________________________________________________________________________________________________________________________________________________________________

8
Chiller AKJ AKC 9series Catalogue DAIKIN EN

Chiller AKJ AKC 9series Catalogue DAIKIN EN

Chiller AKJ AKC 9series Catalogue DAIKIN EN

Chiller AKJ AKC 9series Catalogue DAIKIN EN

Chiller AKW 10series Catalogue DAIKIN EN

Chiller AKW 10series Catalogue DAIKIN EN

Chiller AKZ 10series Catalogue DAIKIN EN

Chiller AKZ 10series Catalogue DAIKIN EN

Chiller AKZ 9series Catalogue DAIKIN EN

Chiller AKZ 9series Catalogue DAIKIN EN

Chiller AKJ 10series Catalogue DAIKIN EN

Chiller AKJ 10series Catalogue DAIKIN EN

Catalog Hybrid System DAIKIN EN

Catalog Hybrid System DAIKIN EN

Long Life Filter DAIKIN EN

Long Life Filter DAIKIN EN